1800 773 743

W&H LYLA – 17L or 22L S-Class Steriliser

W&H LYLA – 17L or 22L S-Class Steriliser

W&H LYLA – 17L or 22L S-Class Steriliser

Siginificant for your needs

S type sterilisation made by W&H is a safe and sustainable way to reprocess items, both wrapped and unwrapped. The Lyla steriliser enormously facilitates daily activities thanks to fast cycles, effortless interaction, reduced maintenance and additional upgrade functions to fulfil your individual needs.

Discover upgradeability

The Lyla steriliser offers the best cycle time in its segment and impresses through its upgradeability. The Activation Code system provides Activation Codes that offer a tailored opportunity to enhance additional features that meet your practice needs and comply with future requirements. Effectively, for customising and upgrading your steriliser.

Smart upgrades


From S to B:
Needs and requirements may change. Prepare yourself now with Lyla. With the Activation Code system, additional functions can be activated according to your needs. The “B cycle” feature upgrades Lyla simply and quick to a B type steriliser according to EN 13060. Lyla will be a strong teammate to speed up your daily activities. Today and tomorrow. Convince yourself!

Take a look at the Lyla Brochure

This product is currently out of stock and unavailable.

0000

Reliable and safe sterilisation with Lyla

In the reprocessing workflow, the sterilisation of your dental instruments is deeply important.

That is why we aim for best standards.

Lyla reduces the risk of infection through its

The Lyla steriliser impresses through its upgradeability

Effectively, for customising and upgrading your steriliser,
the Activation Code system provides Activation Codes
that offer a tailored opportunity to enhance additional features. The “B cycle” feature simply and quickly upgrades Lyla to a B type steriliser according to EN 13060.

Smart upgrades

The Lyla steriliser impresses through its upgradeability

Effectively, for customising and upgrading your steriliser,
the Activation Code system provides Activation Codes
that offer a tailored opportunity to enhance additional features. The “B cycle” feature simply and quickly upgrades Lyla to a B type steriliser according to EN 13060.

Super fast cycle

A strong teammate to speed up your  daily activities

Lyla offers the best cycle times in its segment.

The different available cycles guarantee the possibility to sterilise several instrument types, including hollow bodies, both wrapped, unwrapped or placed in containers.

The gentle cycle ensures the sterilisation of sensitive items and porous load, such as surgical clothes.

Secure traceability

Lyla improves your traceability system

The label printer can be connected to the steriliser for printing barcodes. In combination with the integrated data logger, it improves your traceability system.

Thanks to the barcode reader you can scan labels into patient records – an easy tool to link cycle, sterilisation package and patient.

 

Simple operation

High operating comfort

The simplified menu structure ensures extraordinarily high operating comfort: you can quickly navigate to programs and settings using the 3.5“ colour touch screen.

 

Colour touch screen
The Lyla colour touch screen has been selected and designed to make your daily work easier, faster and more efficient.

Simple water filling
The water tank cover can be easily removed without tools, thus manual water filling is simple with the integrated funnel.

Time-saving maintenance
The smooth surface design and ergonomic shape enables easy cleaning and, thanks to modular feet, it fits in anywhere.

Integrated data logger
Improves your traceability system

Extended connectivity
With the W&H Steri App

Service interval
Thanks to the high level of reliability, the service interval is set to 4,000 cycles or 5 years.

Discover upgradeability

Needs and requirements may change. Prepare yourself now with Lyla.

With the smart Activation Code system, additional functions can be activated according to your needs.

The four additional features at a glance:

The “B cycle”
feature upgrades Lyla to B type steriliser according to
EN 13060.

Remote data storage
offers the possibility to save cycles directly on PC.

The “Traceability”
feature enables user identification and load release confirmation.

The All in One feature provides all benefits at once – and ultimately your steriliser becomes an unattainable price-performance ratio.

Lyla sterilisation programs

Sterilisation cycle S Wrapped 134 S Prion 134 S Gentle 121 S Unwrapped 134
Temperature: 134 °C 134 °C 121 °C 134 °C
Holding time (minutes): 4 18′ 30” 20′ 30” 4
Total cycle duration
(minutes) including
complete drying:
Automatic from Typical
load
Automatic from Typical
load
Automatic from Automatic from Typical
load
Lyla 17
38′ to 45′
42′
52′ to 59′
56′ 61′ to 64′ 20′ to 26′ 23′
Lyla 22
39′ to 46′
43′
53′ to 60′
57′ 62′ to 66′ 21′ to 27′ 24′
Lyla 17/22 loads:
maximum solid 4 kg/typical 2 kg/maximum porous 0.5 kg
maximum 4 kg unwrapped
Lyla 17/22 containers load: maximum 4 kg not applicable
Test cycles: Bowie and Dick/Vacuum test

Items supplied with reversible rack, 3 aluminium trays, drain tube, tray holder, 8 GB USB drive, door opening tool, factory test

Lyla Steriliser

Lyla 17 Lyla 22
Type: RIN-210 RIN-210
Chamber size: 17 l 22 l
Power supply: 200–240 V AC; 50/60 Hz; 10 A single phase
Power consumption: 2.0–2.4 kW
Overall dimension
(width × height × depth):
465 × 452 × 646 mm
Weight: 40 kg 42 kg
Main / Used water tanks: 4.8/4.8 l
Working range: 7 to 10 cycles
Usable space
(width × height × depth):
195 × 195 × 400 mm (1)
Connection types: 1 USB port in the front (additional 1 in the rear as option), automatic water filling kit (optional)

(1) Usable space is referred to standard rack configuration.

Lisa sterilisers were designed, certified and validated with the most stringent directives and standards:
93/42/EEC Medical Device Directive
2014/68/EU Pressure Equipment Directive
EN 13060 Small steam steriliser
IEC 61326-1 Electromagnetic compatibility
IEC 61010-1 Safety requirements steriliser
IEC 61010-2-040 Specific requirements for steam steriliser
IEC 61770 Electric appliances connected to the water mains

The steriliser can be validated according to EN ISO 17665-1

Additional information

Chamber size

Lyla 17, Lyla 22